Celebrate your confidence, embrace your beauty

Take your practice to the next level

Motiva® Implants Overview

Explore our breast reconstruction and augmentation solutions designed with high-end technology and research-based knowledge focused on improving patient safety and aesthetic outcomes.

Technology

INCLUDED

ADD-ONS

Motiva® Round Plus

Balanced softness and firmness with a full and round upper breast

- TrueMonobloc® - ProgressiveGel® PLUS - BluSeal® - SmoothSilk®/SilkSurface®

- Product Replacement Policy - Always Confident Warranty® - RFID Enabled Implant (Qid®)

- RFID-Enabled Implant (Qid®) - Motiva MinimalScar® - 2Y Extended Warranty* - 5Y Extended Warranty**

Motiva Ergonomix®

Designed to mimic the look, feel, and movement of natural breast tissue

- TrueMonobloc® - ProgressiveGel® ULTIMA - BluSeal® - SmoothSilk®/SilkSurface®

- Product Replacement Policy - Always Confident Warranty® - RFID Enabled Implant (Qid®)

- RFID-Enabled Implant (Qid®) - MotivaHybrid® - Motiva MinimalScar® - 2Y Extended Warranty* - 5Y Extended Warranty**

Motiva Ergonomix2®

Designed for improved ergonomy and an even softer implant than Ergonomix®

- Motiva SuperSilicones® - TrueMonobloc+® - ProgressiveGel Ultima® - BluSeal+® - SmoothSilk®/SilkSurface®

- JOY® Program  • Woman’s Choice Program®  • 5Y Extended Warranty - RFID-Enabled Implant (Qid®) - Product Replacement Policy - Always Confident Warranty®

- MotivaHybrid® - Motiva MinimalScar®

*Add-on option for implants without Qid®

**Add-on option for implants with Qid®

Breast Optimization

More about implant technology

Motiva SuperSilicones®

Breast implant shell quality is an essential safety feature and is also key to providing flexibility and other mechanical properties crucial for the device’s performance.4

With the Ergonomix2® implants, Motiva® is introducing a new silicone formulation and shell configuration that improves elongation,5 enhancing its ability to adapt to changes.

Why is this important? The ability to bend easily is essential for the implant to be introduced through small incisions. Ergonomix2® is an implant designed to enhance minimally invasive techniques like Motiva MinimalScar®.

TrueMonobloc+®

This feature is a proprietary technology that links the components of the shell and the filling gel to create a more cohesive structure.1

The interaction between the unique features of the components in Ergonomix2® maximizes its bonding properties while conferring the system with more flexibility and adaptability. This gives rise to an upgraded version named TrueMonobloc+®.

Ergonomix2® implants can be compressed to a higher degree than our trusted high-performing Ergonomix®, thus facilitating the insertion of the device through smaller incisions.6

BluSeal+®

For more than three decades, technology advancements have led to a significant improvement in control of silicone diffusion from breast implants.7

Our safety barrier layer is one-of-a-kind. It is a lightly tinted, blue-barrier layer made with biocompatible dyes to allow for pre-surgical visual inspection.1

BluSeal+® improves the performance of an already outstanding safety feature.8

ProgressiveGel Ultima®

Natural tissue dynamics resemblance has been the key missing factor in traditional implants due to their predefined shape, which remains unaltered whether the patient is standing up, inclined or lying down.

Motiva® incorporates this organic movement characteristic into Ergonomix2® through the unique viscoelastic properties of the Ultima® gel – holding a round shape when the patient is lying down and forming a natural looking teardrop shape when she is standing.9

The outcome is a gel created with a unique set of properties that provide a better adaptation to movement than other silicone gels tested, resembling the mobility of natural tissue.1

SmoothSilk®/SilkSurface®

An advanced smooth surface designed to enhance biocompatibility.2

Ergonomix2® comes with SmoothSilk®/SilkSurface®, a controlled uniform surface designed and demonstrated to:
• Mitigate the inflammatory and fibrotic response of your body.10
• Limit bacterial load, reducing the risk of biofilm formation.11
• Reduce the prevalence of chronic inflammatory complications, such as double capsules and late seromas.12

RFID-enabled Implants

The electronic serial number (ESN) and related information about your implants is kept safely through a battery-free and passive radiofrequency identification device3: our Qid®.

This first-of-its-kind safety technology allows your healthcare provider to use an external, hand-held reader to identify details about your Motiva Implants after surgery, even if your printed implant ID card isn’t available.

Did you know?

A most recent study performed at the Koch Institute from MIT, published in the Nature Biomedical Engineering Journal, observed in vivo physiological and immune responses in mice, rabbits, and explanted capsules from human models with different silicone breast implant surface architectures, ranging from traditional smooth, to advanced smooth, to micro or macro/heavily textured.2

Findings suggest that SmoothSilk®/SilkSurface® implants showed improved biocompatibility as:

  • SmoothSilk®/SilkSurface® provoked the less pro-fibrotic inflammation and FBR across mouse and rabbit models and human capsules.
  • Its profile is characterized by a low inflammatory cell infiltrate and anti-fibrotic gene expression.
  • This in turn should minimize foreign body immune-related complications, such as capsular contracture, malposition, seroma, double capsule, and BIA-ALCL.2

Why Motiva®

Let Patients Find You

Leverage the popularity of Motiva® with potential patients all over the world. Help them find you by listing your practice in our Center Locator.

Digital Transformation

Gain access to our Resource Center, filled with marketing and social media content to help market your practice.

Broaden Your Horizons

Keep your skills scalpel sharp with our continuing medical education platform MotivaEDGE®. Be part of the conversation with our global webinars and live events.

References

1 Data on file. Establishment Labs®.

2 Doloff JC, Veiseh O, de Mezerville R, et al. The surface topography of silicone breast implants mediates the foreign body response in mice, rabbits and humans. Nature Biomedical Engineering. 2021;5(10):1115-1130. doi:10.1038/s41551-021-00739-4

3 Nelson MT, Brattain KA, Williams JM. Does Electronic Identification Enablement for Silicone Gel Implants Impact Patient Safety? J Surg Open Access. 2018;4(1):1-7. doi:10.16966/2470-0991.162

4 Patrick Maxwell G, Gabriel A. Breast implant design. Gland Surg. 2017;6(2):148-153. doi:10.21037/gs.2016.11.09

5 Establishment Labs. TS-001196. Mar, 2021.

6 Establishment Labs. TS-000212. Mar, 2021

7 Spear SL, Jespersen MR. Breast implants: Saline or silicone? Aesthetic Surg J. 2010;30(4):557-570. doi:10.1177/1090820X10380401

8 Establishment Labs. TSD-001008. Nov, 2020.

9 Pluris Research Inc. ELABS2. Apr, 2018.

10 Quirós MC, Bolaños MC, Fassero JJ. Six-year prospective outcomes of primary breast augmentation with nano surface implants. Aesthetic Surg J. 2019;39(5):495-508. doi:10.1093/asj/sjy196

11 James GA, Boegli L, Hancock J, Bowersock L, Parker A, Kinney BM. Bacterial Adhesion and Biofilm Formation on Textured Breast Implant Shell Materials. Aesthetic Plast Surg. 2019;43(2):490-497. doi:10.1007/s00266-018-1234-7

12 Sforza M, Zaccheddu R, Alleruzzo A, et al. Preliminary 3-Year Evaluation of Experience with SilkSurface and VelvetSurface Motiva Silicone Breast Implants: A Single-Center Experience with 5813 Consecutive Breast Augmentation Cases. Aesthetic Surg J. 2018;38:S62-S73. doi:10.1093/asj/sjx15

404

No results were found

The page you requested could not be found. Use the button below or the navigation to get back on track.

This information is intended solely for the use of healthcare professionals. A healthcare professional must always rely on his or her own professional clinical judgment when deciding whether to use a particular product when treating a particular patient. Motiva® does not dispense medical advice and recommends that healthcare professionals be trained in the use of any particular product before using it in a procedure or surgery. A healthcare professional must always refer to the package insert, product label and/or instructions for use before using any Motiva® product. The information presented is intended to demonstrate particular products, as well as the breadth of Motiva® product offerings. Products may not be available in all markets because product availability is subject to the regulatory and/or medical practices in individual markets. Please contact your local representative if you have questions about the availability of specific products in your area. Motiva® products that are CE marked are marked according to the applicable EU Regulations and Directives.